Actuator, RECIRCULATION Door: Removal
WARNING:
Disable the airbag system before attempting any steering wheel, steering column, or instrument panel component diagnosis or service. Disconnect and isolate the negative battery (ground) cable, then wait two minutes for the airbag system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system. Failure to follow these instructions may result in accidental airbag deployment and possible serious or fatal injury.
- Disconnect and isolate the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), disconnect the IBS connector first before disconnecting the negative battery cable.
- Remove the glove box. Refer to GLOVE BOX, INSTRUMENT PANEL, REMOVAL .
- Disconnect the HVAC wire harness connector (3) from the recirculation door actuator (1).
- Remove the two screws (4) that secure the recirculation door actuator to the air inlet housing (2) and remove the actuator.