Home >> Dodge and Ram >> 2018 >> Charger Pursuit, 5.7L Eng VIN T, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 8 (8HP70 Automatic Transmission (Service Information)) >> Cable, Manual Park Release >> Installation >> MPR Cable

MPR Cable

WARNING: This page is about a different variant/trim than selected.
GC0152190Courtesy of CHRYSLER GROUP, LLC
  1. Install the Manual Park Release (MPR) cable (2) in the vehicle. Install the MPR cable bracket bolts (1) and tighten to the proper specification. Refer to TECHNICAL SPECIFICATIONS .
    GC0152189Courtesy of CHRYSLER GROUP, LLC
  2. Connect the MPR cable (1) to the MPR lever (2).
  3. Lower the vehicle.
    GC0152223Courtesy of CHRYSLER GROUP, LLC
  4. Connect the MPR cable (2) to the MPR lever.
  5. Connect the MPR cable (1) to the housing.
  6. Install the MPR cover.
  7. Connect the negative battery cable.