Floor Console
NOTE:
Take the proper precautions to protect the face of the floor console end cap from cosmetic damage while performing this procedure.
- Position the air outlet (2) onto the floor console end cap (1).
- Engage the retaining tabs (3) that secure the air outlet to the trim panel. Make sure the retaining tabs are fully engaged to the outlet.NOTE:
Make sure that the air outlet is properly aligned to the duct within the floor console and that the foam seal on the duct is properly installed.
- Install the console end cap (1) onto the back of the floor console. Refer to CONSOLE, FLOOR, INSTALLATION .
- Connect the negative battery cable.