Actuator, RECIRCULATION Door: Installation
- Position the recirculation door actuator (1) to the recirculation door pivot shaft (4).
- Install the recirculation door actuator onto the HVAC air inlet housing (2). If necessary, rotate the actuator slightly to align the splines on the actuator output shaft (3) with those on the recirculation door pivot shaft (4).
- Install the two screws (4) that secure the recirculation door actuator (1) to the air inlet housing (2) and securely tighten the screws.
- Connect the HVAC wire harness connector (3) to the recirculation door actuator.
- Install the glove box. Refer to GLOVE BOX, INSTRUMENT PANEL, INSTALLATION .
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.
- Initiate the Actuator Calibration function using a scan tool. Refer to STANDARD PROCEDURE .