Suction Line

GC0158228Courtesy of CHRYSLER GROUP, LLC
  1. Position the front section of the suction line into the engine compartment.
  2. Remove the tape or plugs from the fittings that connect the suction line to the Internal Heat Exchanger (IHX).
  3. Lubricate a new dual plane seal with clean refrigerant oil and install it onto the suction line fitting. Use only the specified seal as it is made of a special material for the specific refrigerant in the system. Use only refrigerant oil of the type recommended for the A/C compressor in the vehicle.
  4. Connect the suction line to the Internal IHX (1).
  5. Install the nut (3) that secures the suction line to the IHX and tighten to the proper torque specifications. Refer to TORQUE SPECIFICATIONS .
  6. Remove the tape or plugs from the fitting on the suction line and the inlet port of the A/C compressor.
  7. Lubricate a new dual plane seal with clean refrigerant oil and install it onto the suction line fitting. Use only the specified seal as it is made of a special material for the specific refrigerant in the system. Use only refrigerant oil of the type recommended for the A/C compressor in the vehicle.
    GC0158240Courtesy of CHRYSLER GROUP, LLC
    NOTE:

    3.6L compressor and refrigerant lines shown in the illustration.

  8. Connect the suction line (2) to the A/C compressor.
  9. Install the nut (1) that secures the suction line to the A/C compressor and tighten to the proper torque specifications. Refer to TORQUE SPECIFICATIONS .
  10. Install the air cleaner housing. Refer to BODY, AIR CLEANER, INSTALLATION .
  11. Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.
  12. Evacuate the refrigerant system. Refer to PLUMBING, STANDARD PROCEDURE .
  13. Adjust the refrigerant oil level. Refer to OIL, REFRIGERANT, STANDARD PROCEDURE .
  14. Charge the refrigerant system. Refer to PLUMBING, STANDARD PROCEDURE .